Strain gauge test output for Beam 6 ( 6 (2-Mid / 2-Right / 2-left) Expantion Anchors - Hex Head 3/8") / LVDT          
Anchors Tighten Strength  Strain No. Strain Location CH. No. StrainTest Results  LVDT Voltage 
No Load 1 Side face - Top 0 1.3868 m -1.088
No Load 2 Side face - Bottom 1 40.3535 u  
1 1 Side face - Top 0 1.3857 m -1.0887
1 2 Side face - Bottom 1 38.9321 u  
2 1 Side face - Top 0 2.8109 m -1.0887
2 2 Side face - Bottom 1 35.7374 u  
3 1 Side face - Top 0 2.8163 m -1.0893
3 2 Side face - Bottom 1 36.4456 u  
4 1 Side face - Top 0 2.8217 m -1.0883
4 2 Side face - Bottom 1 33.7812 u  
5 1 Side face - Top 0 2.8217 m -1.0882
5 2 Side face - Bottom 1 32.5216 u  
6 1 Side face - Top 0 2.8283 m -1.089
6 2 Side face - Bottom 1 31.4872 u  
7 1 Side face - Top 0 2.8380  m -1.0883
7 2 Side face - Bottom 1 29.0279 u  
8 1 Side face - Top 0 2.8576 m -1.0913
8 2 Side face - Bottom 1 36.0435 u  
9 1 Side face - Top 0 2.8654 m -1.0965
9 2 Side face - Bottom 1 42.2992 u  
10 1 Side face - Top 0 2.8736 m -1.0883
10 2 Side face - Bottom 1 45.9127 u  
11 1 Side face - Top 0 2.8752 m -1.0885
11 2 Side face - Bottom 1 45.9092 u  
12 1 Side face - Top 0 2.8987 m -1.0882
12 2 Side face - Bottom 1 46.2047 u  
13 1 Side face - Top 0 2.9064 m -1.8817
13 2 Side face - Bottom 1 46.5742 u  
14 1 Side face - Top 0 2.9063 m -1.0892
14 2 Side face - Bottom 1 38.9884 u  
15 1 Side face - Top 0 2.9077 m -1.0894
15 2 Side face - Bottom 1 37.8594 u